MPT Series · Dynamic pressure

High-Frequency Dynamic Pressure Sensors for Aerospace and Test Applications

The Dabey MPT series is designed for high-frequency dynamic pressure measurement in aerospace, aero engine, wind tunnel, hydraulic and industrial test systems. MPT sensors are selected around the actual test condition: pressure range, transient event, frequency requirement, operating temperature, installation space, output signal and data acquisition compatibility.

MPTW100 high-frequency dynamic pressure sensor for aerospace testing
Product family
MPT Series High-Frequency Dynamic Pressure Sensors
Measurement type
Time-resolved (dynamic) pressure, not steady-state only
Typical applications
Aero engine, gas turbine, wind tunnel, hydraulic transient and landing gear testing
Selection inputs
Pressure range, frequency response, temperature, mounting, output and connector
Cross-reference
Evaluation against an existing Kulite, Druck or other sensor datasheet
Support
Configuration review before quotation; no blanket replacement claim

When a static pressure sensor is not enough

Static pressure measurement focuses on a stable or slowly changing pressure value. The number of interest is the average, and a transmitter optimised for accuracy and long-term stability is the right instrument.

Dynamic pressure measurement focuses on how pressure changes over time during an event. Combustion pulsation, aerodynamic loading, hydraulic spikes, pressure waves and impact-related events can require a sensor and a measurement chain with suitable frequency response, mounting geometry and signal compatibility. A sensor that is accurate to 0.1 %FS can still be the wrong choice if it smooths a 3 kHz pulsation into a flat line.

Four elements set the usable bandwidth of a dynamic pressure channel, and the weakest one decides the result:

  1. The sensing element and diaphragm. A small, stiff diaphragm moves the mechanical resonance up, which is why miniature bodies are used where fast events matter.
  2. The oil fill and the pressure port cavity. The cavity in front of the diaphragm behaves like an acoustic volume. A long, narrow passage attenuates high frequencies and can add a resonance of its own.
  3. The electronics. On the MPTW models, the amplified outputs are specified at about 10 kHz at −3 dB, while the bridge outputs are limited by the port and the medium rather than by the circuit.
  4. The cable and the data acquisition. Sampling at only twice the highest frequency of interest gives two points per cycle — enough to see that an event occurred, not enough to measure its amplitude or shape.

A practical rule: sample at five to ten times the highest frequency you need to resolve, and keep the pressure path short and straight. If a sensor has to sit behind an adapter or a long drilled passage, treat the published bandwidth as an upper bound and verify the installed response on the rig.

High-frequency dynamic pressure measurement by application

The same sensor family is used across these test types, but the mounting, the port and the temperature protection differ. Each case below describes what actually decides the configuration.

Aero engine and gas turbine testing

Combustor dynamics, compressor surge and turbine blade-passing pressure are the three measurements that most often call for a dynamic sensor. Combustor instability typically sits between a few hundred hertz and about 5 kHz, which is inside the range of a 10 kHz transducer; blade-passing frequencies can be higher and usually need a different, purpose-built probe.

The constraint in an engine test cell is rarely bandwidth. It is temperature and access. A casing boss may run well above 150 °C even when the gas path is hotter still, so the sensor is normally mounted behind a cooled adapter or a short waveguide, and the first metre of cable is the part that fails if it is not rated for the environment. Specify the sensor, the adapter and the cable as one assembly rather than three separate purchases.

Dynamic pressure sensors for aero engine testing →

Wind tunnel and aerodynamic testing

Wind tunnel work usually needs two different things from the same page: steady surface pressure for pressure distributions, and unsteady pressure for buffeting, separation and acoustics. Steady taps can be routed to a scanner; unsteady taps need the sensor close to the surface, because tubing acts as a low-pass filter and shifts phase.

On model scale, mass and size dominate. A 24.5 g body mounted inside a small model changes the model's own dynamics; the ultraminiature UPT200 at 0.6 g and Ø1.70 mm exists for exactly this case. Where a standard body fits, MPTW100 with a short flush port is the simpler and more robust choice. In both cases, the tubing between the orifice and the diaphragm should be as short as the model allows.

Miniature pressure transducers for wind tunnel measurement →

Hydraulic transient and landing gear testing

Water hammer, valve closure, pump ripple and accumulator behaviour produce short, high-amplitude peaks on a high static line pressure. Two specifications matter more than accuracy here: the overload margin and the burst pressure. MPTW models are rated for 2×FS overload and 3×FS burst, so a 35 MPa range can survive the spikes that would destroy a transmitter specified only at full scale.

In landing gear drop and fatigue rigs, the same channels cover shock absorber and brake pressure, and differential measurement across a damper orifice is often more useful than either absolute reading. MPTWD250 covers dry-dry, dry-wet and wet-wet differential configurations, which keeps the specification decision about the medium rather than the price.

Dynamic hydraulic pressure sensors for landing gear testing →

How to select an MPT dynamic pressure sensor

Work through the six items below in order. The first three usually eliminate most of the range before electronics are discussed.

  1. Pressure range and overload. Choose the smallest full scale that covers the highest expected peak, then check the 2×FS overload and 3×FS burst. A range that is too wide costs resolution; one that is too narrow risks the diaphragm on the first spike.
  2. Event frequency and required bandwidth. Estimate the highest frequency you need to resolve, not the highest frequency present. Then confirm that the installed response — port included — covers it, and set the sample rate at five to ten times that figure.
  3. Medium and port acoustics. Gas and liquid behave differently in the cavity in front of the diaphragm. Liquid-filled ports are typically better behaved at high frequency; gas-filled ports are more sensitive to cavity volume and passage length.
  4. Temperature. 150 °C is the sensor limit across this family. If the mounting boss runs hotter, plan a cooled adapter, a heat shield or a stand-off, and check the cable and connector rating as well.
  5. Mounting and installation space. Body mass ranges from 13 g to 140 g, and the port options range from M5×0.8 to M10×1 and 3/8-24 UNJF. On thin walls and small models, the added mass and the boss stiffness change the measurement.
  6. Output, connector and DAQ. Bridge outputs need a high-impedance amplifier; amplified outputs below 150 Ω drive a standard DAQ directly and carry the 10 kHz figure. Decide this before the connector, because the two are specified together.
Selection inputQuestion to answerTypical value in this family
Pressure rangeWhat is the highest peak, including spikes?0–10 kPa to 0–70 MPa
OverloadWhat happens on the first pressure surge?2×FS overload, 3×FS burst
BandwidthWhat is the highest frequency to resolve?≈10 kHz @ −3 dB (amplified outputs)
TemperatureHow hot is the mounting boss, not the gas?−55 to 150 °C
MassDoes the body change the structure?13 g to 140 g, 0.6 g for UPT200
OutputBridge amplifier or direct DAQ?S1–S6 depending on model

Values are model-dependent. Confirm the exact configuration against the individual datasheet before ordering.

MPT series high-frequency dynamic pressure sensors

This overview is a routing page, not a specification sheet. Each model page carries the full range table, drawing, connector definition and datasheet.

Cross-reference support for existing dynamic pressure sensors

Most of our dynamic pressure enquiries start with a sensor that is already in the test cell. The customer has a Kulite, Druck or another model, the rig is built around it, and the question is whether an equivalent can be supplied without redesigning the installation.

We review the existing sensor rather than the brand name. Send the datasheet or the full model code, and we compare pressure range, proof and burst pressure, pressure port and thread, electrical output, temperature class, body size and connector. Where a parameter does not match, we say so before quoting, because a sensor that fits the thread but not the amplifier is not a replacement.

The mappings we have already documented are listed on the individual cross-reference pages: Kulite XCQ-062, HKM-375, ETM-375, XTL-100-190 and ETM-634-312. Druck and other brands are evaluated from the datasheet, since the equivalent depends on the port and output combination rather than the model family alone.

Existing modelDabey equivalentTypical reason for the swap
Kulite XCQ-062 UPT200 0.062" ultraminiature body, 0.6 g, model-scale installation
Kulite HKM-375 MPTW100 0.375" body, M10×1 port, 10 kHz electronics
Kulite ETM-375 MPTW100 Same body class and pressure range
Kulite XTL-100-190 MPTW500 13 g miniature body for engine and rig installations
Kulite ETM-634-312 MPTW800 Compact body with a single amplified output

We do not claim a 100 % replacement. Cross-reference is an engineering review of the test condition, and the final configuration is confirmed after the pressure range, temperature, mounting and signal requirements have been checked.

Frequently asked questions about dynamic pressure sensors

What is a high-frequency dynamic pressure sensor?

A pressure sensor built to reproduce pressure as a function of time, rather than to report an average. It combines a small, stiff diaphragm with electronics and a pressure path that together preserve fast changes — typically into the kilohertz range. The MPT series amplified outputs are specified at about 10 kHz at −3 dB; the usable figure after installation depends on the port and the medium.

What is the difference between static and dynamic pressure measurement?

Static measurement is concerned with a steady or slowly changing value, so accuracy and long-term stability dominate. Dynamic measurement is concerned with the shape of an event, so bandwidth, phase behaviour, port geometry, sampling rate and overload margin dominate. A transmitter that is excellent for the first task can be useless for the second.

How do I choose a dynamic pressure sensor for aero engine testing?

Start from the frequency of the phenomenon — combustor instability is usually a few hundred hertz to about 5 kHz — then check the mounting boss temperature, the available space and the port thread. In practice the sensor is mounted behind a cooled adapter or a short waveguide, so specify the adapter and the first cable section with the sensor rather than separately.

Which MPT sensor is suitable for wind tunnel pressure measurement?

For wall taps and larger models, MPTW100 with a short flush port is the straightforward choice. For model-scale work where mass and size change the model's own dynamics, the ultraminiature UPT200 at 0.6 g and Ø1.70 mm is the better starting point. In both cases keep the tubing between the orifice and the diaphragm as short as the installation allows.

Can Dabey cross-reference an existing Kulite or Druck pressure sensor?

Yes. Send the current model number or datasheet and we compare the application, pressure range, output, mounting, connector, temperature and frequency-response requirements before recommending an MPT configuration. Where a parameter does not match, we will tell you before quoting.

What information is required before ordering a dynamic pressure sensor?

Pressure range and peak level, the medium, the mounting boss temperature, the frequency you need to resolve, the available space and thread, the required output type, and the data acquisition input. A sketch of the installation is more useful than a long description, and a screenshot of the existing sensor datasheet is usually enough to start a cross-reference.

Send the test condition, not just the model number

Pressure range, peak level, medium, mounting temperature, frequency to resolve and thread are enough to recommend a configuration. If you already have a sensor, upload its datasheet and we will return a line-by-line comparison.

We’re not just a supplier, we’re an extension of your success!

Get a Quick Quote!

We’ll be reply  your email within 24 hour, thanks for waiting。