Cross-Reference

Kulite Pressure Transducer Replacement Guide

Kulite is a well-known manufacturer of miniature and ultraminiature pressure transducers used widely in aerospace, test, and research applications. This page maps published Kulite model numbers to DABEY alternatives, with a specification comparison for each one.

  • 5 Kulite model families mapped
  • Millivolt bridge and amplified outputs
  • Absolute, gauge, and sealed gauge
  • Specs sourced from published datasheets

Kulite Models and DABEY Alternatives

Click any DABEY model for the full side-by-side specification comparison.

Kulite model DABEY alternative Output type Kulite pressure range DABEY standard coverage
XCQ-062 UPT200 Millivolt bridge 5–1000 PSI 5–1000 PSI
HKM-375 MPTW100 Millivolt bridge 100–20,000 PSI 0–2 to 0–70 MPa
ETM-375 MPTW100 5 V amplified 100–20,000 PSI 0–2 to 0–70 MPa
XTL-100-190 MPTW500 Millivolt bridge 10–2000 PSI 0–2 to 0–70 MPa
ETM-634(X)-312(M) MPTW800 Amplified 290–5076 PSI 0–2 to 0–70 MPa

Ranges shown are as published by each manufacturer. Where ranges differ, customized ranges may be available.

  • Millivolt bridge transducer? The DABEY equivalent is a millivolt output variant such as UPT200, MPTW100 S1/S2, or MPTW500 S1/S2. It requires stable excitation and clean shielding.
  • Amplified transducer? The DABEY equivalent is an amplified variant such as MPTW100 S4–S6 or MPTW800 S4, which includes on-board conditioning.
  • Starting point. Match the output type first, then the pressure range, then the mechanical interface. Most mismatches come from the last step, not the first.

How to Find Your Replacement

  1. Identify the original model number. It is stamped on the transducer body or printed on the calibration certificate.
  2. Open the matching comparison page. Published specifications are listed side by side, including accuracy, impedance, temperature, weight, and mounting.
  3. Confirm the four critical parameters. Reference type, pressure range, output and impedance, and mechanical interface. Everything else follows.
  4. Request a fit check. Send your range, output, temperature window, and mounting constraints. We confirm the closest configuration and return a drawing.

What to Check Before Replacing a Kulite Sensor

Reference type

Absolute, gauge, and sealed gauge are available across the range. This is the first parameter that rules a sensor in or out.

Output and impedance

Millivolt bridge and amplified outputs behave differently at the data acquisition end. Match the output type and check input and output impedance against your system.

Mechanical interface

Thread, hex size, insertion depth, and O-ring dimensions decide whether a swap is possible at all. Check against your assembly drawing.

Temperature and media

Compensated temperature windows and wetted materials vary by model. Confirm both against your process conditions.

Source and Verification

Competitor specifications: all Kulite values shown across this section are taken from published Kulite datasheets. Each comparison page links to its source.

DABEY specifications: taken from the DABEY datasheets for each product. View all datasheets

Last verified: 2026-09-15

Talk to an applications engineer

Send your current sensor model and application details. We will confirm the closest DABEY alternative, return the datasheet and drawing, and answer any fit questions.

Talk to an applications engineer

Frequently Asked Questions

Which DABEY product replaces a Kulite pressure transducer?
It depends on the model. Ultraminiature applications map to the UPT200. Miniature threaded transducers map to the MPTW100, MPTW500, or MPTW800 series, depending on range, output type, and temperature requirement. The table above lists the closest alternative for each published model, with a full comparison on the linked page.
Are DABEY replacements mechanically interchangeable?
In many cases the mounting thread and sealing geometry are compatible, but this must be confirmed per model against your assembly drawing. Each comparison page lists thread, O-ring dimensions, mounting torque, and weight so you can check the interface before ordering.
Do you supply samples for validation?
Yes. Contact our applications engineers with your measurement requirement and we will discuss sample units for back-to-back testing in your own fixture.
What about intrinsically safe versions?
Some Kulite models have intrinsically safe options. DABEY datasheets do not list equivalent options for all products, so contact us before specifying a replacement in a hazardous-area application.
What is the delivery time?
Availability and delivery depend on the model, range, output variant, and order quantity. Contact us with your configuration and we will confirm the current delivery estimate.

We’re not just a supplier, we’re an extension of your success!

Get a Quick Quote!

We’ll be reply  your email within 24 hour, thanks for waiting。