Cross-Reference · Kulite

Kulite HKM-375 Replacement: DABEY MPTW100

Looking for a Kulite HKM-375 replacement? The DABEY MPTW100 series is a miniature threaded pressure sensor offered as an alternative for HKM-375 applications. Both use a 100 mV four-arm Wheatstone bridge at 10 VDC excitation, with 3/8-24 UNJF or M10×1 mounting. This page compares published specifications and lists what to confirm before ordering.

  • 100 mV bridge output
  • 10 VDC excitation
  • 3/8-24 UNJF or M10×1
  • Absolute or sealed gauge

Specifications Compared

Side-by-side comparison of published specifications. Kulite values are taken from the published HKM-375 (M) series datasheet.

Parameter Kulite HKM-375 (M) Series DABEY MPTW100
Pressure range 100, 250, 500, 1000, 2500, 5000, 10,000, 20,000 PSI (7–1400 bar) 0–150, 0–300, 0–700, 0–1500, 0–5000, 0–10,000 PSI (0–1 to 0–70 MPa). Custom ranges and units available.
Operational mode Absolute, sealed gauge Absolute or sealed gauge
Over pressure 2 × rated to 1000 PSI (70 bar); 1.5 × rated above 1000 PSI up to 25,000 PSI (1724 bar) 2 × FS
Burst pressure 3 × rated, max 25,000 PSI (1724 bar) 3 × FS
Full-scale output 100 mV (nom.) 0–100 mV (S1, S2)
Rated / max excitation 10 VDC/AC rated; 12 VDC/AC maximum S1: 10 VDC; S2: 8–16 VDC
Input impedance 1000 Ω (min.) > 5000 Ω (S1, S2)
Output impedance 1000 Ω (nom.) 5000 Ω typical (S1, S2)
Residual unbalance / zero ± 5 mV (typ.) Within ± 5% FS, about ± 5 mV at a 100 mV full-scale output
Accuracy (non-linearity, hysteresis, repeatability) ± 0.1% FSO BFSL (typ.); ± 0.5% FSO (max) A2: ± 0.1% FS BFSL; A1: ± 0.2% FS BFSL
Natural frequency (without screen) Greater than 400 kHz Greater than 400 kHz (chip)
Acceleration sensitivity 8.0e-6 to 2.2e-4 %FS/g (varies by range) Not specified in the published datasheet
Insulation resistance 100 MΩ min. @ 50 VDC ≥ 100 MΩ @ 50 VDC
Operating temperature −55 °C to +120 °C −55 °C to +150 °C
Compensated temperature +25 °C to +80 °C (any 100 °F range within the operating range on request) Selectable within −55 °C to +150 °C
Thermal zero shift (per 100 °C) ± 1.8% FS (typ.) — converted from ± 1% FS/100 °F S1, S2: < ± 1.5% FS. S4–S6: total error typ. < ± 0.25% FS, max < ± 0.5% FS
Thermal sensitivity shift (per 100 °C) ± 1.8% FS (typ.) — converted from ± 1% FS/100 °F Included in the total error figures above (S4–S6)
Vibration 20 g peak, sine 10–2000 Hz 20 g peak, sine 10–2000 Hz
Shock 20 g half-sine, 11 ms 50 g half-sine, 11 ms
Weight 17 g (max), excluding cable ≤ 24.5 g (cable and connector additional)
Wetted materials 15-5 PH and 316 stainless steel, or Inconel 625 316L / 17-4PH stainless steel
Pressure media Any liquid or gas compatible with 15-5 PH, 316 SS, or Inconel 625 All fluids compatible with 316L / 17-4PH stainless steel
Mounting thread 3/8-24 UNJF-3A or M10 × 1 P15: 3/8-24 UNJF; P16: M10 × 1; P17: M10
Mounting torque 80 in-lb (max), 9 N·m 10 N·m (0–35 MPa); 22 N·m (35–70 MPa)
O-ring Buna-N, 7.6 mm I.D. × 1.6 mm C.S. 7.65 mm I.D. × 1.63 mm C.S.; material matched to the measured medium
Electrical connection 4-conductor 26 AWG shielded cable, 914 mm C8: 4 × 30 AWG shielded, 1 m (other options available)
Pressure sensing principle Fully active four-arm Wheatstone bridge, dielectrically isolated silicon on silicon Four-arm Wheatstone bridge, silicon MEMS chip
Signal conditioning External signal conditioner recommended (Kulite KSC series) Amplified variants S4, S5, S6 include on-board conditioning

MPTW100 values are taken from the DABEY MPTW100 datasheet. For HKM-375 replacement, the S1 and S2 millivolt output variants are the closest match.

  • Impedance differs. HKM-375 is 1000 Ω input and output; the MPTW100 millivolt variants are above 5000 Ω input and 5000 Ω output typical. Check excitation supply loading.
  • Weight differs. 17 g maximum against ≤ 24.5 g. Evaluate on mass-sensitive installations.
  • Range coverage differs at the top end. HKM-375 extends to 20,000 PSI (1400 bar); the MPTW100 standard range tops out at 0–70 MPa (10,000 PSI).

Range Mapping

Closest MPTW100 standard range for each HKM-375 range. Non-standard ranges and units can be customized.

Kulite HKM-375 range MPTW100 closest standard range Custom option
100 PSI (7 bar)0–1 MPa (0–150 PSI)Available on request
250 PSI (17 bar)0–2 MPa (0–300 PSI)Available on request
500 PSI (35 bar)0–5 MPa (0–700 PSI)Available on request
1000 PSI (70 bar)0–5 MPa or 0–10 MPaAvailable on request
2500 PSI (170 bar)0–35 MPa (0–5000 PSI)Available on request
5000 PSI (350 bar)0–35 MPa (0–5000 PSI)Available on request
10,000 PSI (700 bar)0–70 MPa (0–10,000 PSI)Direct match
20,000 PSI (1400 bar)Above the MPTW100 standard rangeConfirm with engineering

Kulite HKM-375 Replacement: What to Check

Reference type

Both are available in absolute and sealed gauge. Confirm which reference your application requires before anything else.

Mechanical interface

Both offer 3/8-24 UNJF and M10×1 threads with comparable O-ring dimensions. Verify the sealing surface, insertion depth, and O-ring material against your media.

Excitation and impedance

Both use a 100 mV bridge output at 10 VDC, but input and output impedance differ. Confirm the excitation supply and data acquisition front end.

Media compatibility

HKM-375 offers an Inconel 625 wetted option; the MPTW100 uses 316L / 17-4PH. Check against the media in your system.

Source and Verification

Competitor specifications: taken from the published Kulite HKM-375 (M) series datasheet. View source

MPTW100 specifications: taken from the DABEY MPTW100 datasheet. View datasheet

Verified: 2026-09-15

Talk to an applications engineer

Send your pressure range, reference type, output variant, temperature window, and mounting constraints. We will confirm the closest MPTW100 configuration and return the datasheet, drawing, and availability.

Talk to an applications engineer

Frequently Asked Questions

Can the DABEY MPTW100 be used as an alternative for Kulite HKM-375 applications?
The MPTW100 is offered as an alternative for HKM-375 applications. Both use a 100 mV four-arm Wheatstone bridge at 10 VDC excitation, with 3/8-24 UNJF or M10×1 mounting. Confirm the range, reference type, impedance, temperature window, and wetted material against your requirement, then validate side by side in your own fixture.
Do I need a signal conditioner with the MPTW100?
For the millivolt output variants (S1, S2), yes — a stable excitation supply and conditioning are required, as with any millivolt bridge sensor. The MPTW100 also offers amplified output variants (S4, S5, S6) with on-board conditioning, which remove the need for a separate conditioner.
Does the MPTW100 cover every HKM-375 pressure range?
No. The HKM-375 range list extends to 20,000 PSI (1400 bar), while the MPTW100 standard range tops out at 0–70 MPa (10,000 PSI). Non-standard ranges and units can be customized — contact us to confirm coverage above 10,000 PSI.
Is the mounting interface compatible?
Both offer 3/8-24 UNJF and M10×1 threads, comparable O-ring dimensions (about 7.6 mm I.D. × 1.6 mm C.S.), and comparable mounting torque. Verify the sealing surface, insertion depth, O-ring material, and cable routing against your assembly drawing.

We’re not just a supplier, we’re an extension of your success!

Get a Quick Quote!

We’ll be reply  your email within 24 hour, thanks for waiting。