Home/ Pressure Transducers/ High-Purity Pressure Sensors

Semiconductor · High purity

High-Purity Pressure Sensors for Semiconductor Gas and Chemical Delivery

A high-purity pressure sensor is a transducer whose wetted surfaces, internal finish and assembly environment are controlled so the sensor does not add particles, moisture or metallic contamination to the process gas. Dabey builds these sensors for gas panels, bulk gas delivery, chemical delivery lines and specialty gas cabinets, where the pressure range is ordinary but the cleanliness requirement is not. The PK40X is specified per installation: wetted material, surface finish, connection type and leak-rate requirement are agreed before the unit is built, and the agreed values are stated on the certificate rather than assumed.

  • Semiconductor gas delivery
  • Wetted material per gas
  • Face-seal connections
  • Leak rate verified
  • Built to configuration
Product
PK40X high-purity pressure sensor
Measurement type
Gauge or absolute pressure in gas and chemical delivery lines
Wetted materials
Selected against the process gas, confirmed on the datasheet for the ordered configuration
Surface finish
Specified to the customer's contamination budget, not a catalogue default
Connection
Face-seal type selected so the installation has no unnecessary dead volume
Leak integrity
Verified against an agreed test standard; the measured value is recorded on the certificate
Assembly
Cleaning, packaging and assembly conditions agreed in writing before production

Why high purity is a different specification

On a gas panel, a pressure sensor is not judged by accuracy alone. Four properties decide whether it can be installed at all, and each one is set by the customer's process rather than by the sensor catalogue.

Contamination

Particles and outgassing

Internal surfaces must not shed particles or release volatiles into the gas stream. This is controlled by the surface finish, the cleaning process and the materials in contact with the gas — three things that are specified together.

Purge

Dead volume and purging

A cavity in front of the diaphragm traps gas and slows a purge cycle. The connection type and the internal geometry are chosen so the sensor adds as little dead volume as the installation allows.

Compatibility

Corrosion and metallurgy

Corrosive specialty gases and cleaning agents attack the wrong alloy quickly. The wetted material is selected against the actual gas, its concentration and its temperature, not against a generic "stainless steel" label.

Integrity

Leak rate

Leak integrity is a measured number tied to a test standard, not an adjective. An ingress protection rating says nothing about helium leak rate, and the two are not interchangeable.

Where these sensors are installed

Gas panels and gas boxes

Pressure monitoring on the supply and delivery side of process gas panels, where the sensor sits close to valves and mass flow controllers.

Bulk gas and specialty gas delivery

Line pressure at cylinder changeover panels, manifolds and distribution headers serving the fab.

Chemical and precursor delivery

Pressure measurement on liquid precursor and chemical delivery lines, where material compatibility dominates the specification.

Valve manifold boxes and cabinets

Compact installations where the sensor body, the connection and the cable exit all have to fit inside an existing enclosure.

What determines the configuration

Six items. Without them any quotation would be a guess, and a guess in a gas panel is expensive to correct.

ItemWhy it mattersWhat to send
Gas or chemical Decides the wetted alloy and rules out incompatible materials Gas name, concentration, moisture level and temperature
Surface finish Controls particle retention and purge behaviour Required internal finish, or the contamination budget it must meet
Connection Determines dead volume and whether the joint can be purged Connection type and size, or the mating part number
Leak rate Must be verified against a stated method, not assumed Acceptable leak rate and the test standard to be used
Pressure and temperature Sets the range, the overload margin and the compensated band Normal and peak pressure, plus the line temperature
Output and electrical Must match the controller or DAQ already in the panel Supply voltage, output signal, connector type

Where a value cannot be met, we say so before quoting. A sensor that fits the connection but not the contamination budget is not a replacement.

PK40X high-purity pressure sensor

One product line, configured per installation. The figures below are confirmed against the ordered configuration rather than published as a single catalogue rating.

PK40X

PK40X

High-purity pressure sensor for semiconductor gas and chemical delivery

  • Pressure rangePer datasheet
  • Wetted materialPer gas / per order
  • Surface finishPer contamination budget
  • ConnectionFace-seal, size per installation
  • Leak integrityVerified per agreed standard
  • OutputPer datasheet

View the PK40X product page →

What we do not claim on this page: a surface roughness figure, a cleanliness class or a certification number that is not stated on the certificate for the ordered configuration. Those values are confirmed in writing during quotation, and they appear on the document that ships with the sensor.

Frequently asked questions

What does “high purity” mean for a pressure sensor?

It means the wetted surfaces, internal finish and assembly conditions are controlled so the sensor does not introduce particles, moisture or metallic contamination into the process gas. The requirement is defined by the customer's process — gas, concentration, contamination budget and purge strategy — rather than by a single industry-wide number.

Which wetted materials are available?

The alloy is selected against the actual gas or chemical and its temperature. Send the medium and we will confirm which material applies to your installation, together with the connection and the sealing arrangement.

What surface finish can you supply?

It is specified to the contamination budget of the installation rather than offered as a catalogue default. Tell us the required finish or the specification it has to meet and we will confirm what can be achieved for that body and connection.

How is leak integrity verified?

Against a helium leak test using an agreed standard and acceptance value. The measured result is recorded on the certificate that ships with the unit. An ingress protection rating is not a substitute for this test and is not used as one.

Can you cross-reference an existing UHP pressure sensor?

Yes. Send the existing model code or datasheet and we compare the pressure range, wetted material, surface finish, connection, leak requirement and electrical output. Where a parameter cannot be matched, we will say so before quoting rather than after delivery.

What information is needed before quotation?

The gas or chemical, its concentration and temperature, the required internal finish, the connection type, the acceptable leak rate with its test standard, the pressure range and the electrical output. A drawing of the installation is more useful than a long description.

We’re not just a supplier, we’re an extension of your success!

Get a Quick Quote!

We’ll be reply  your email within 24 hour, thanks for waiting。